FOUL ANCHOR/CHAIN AWARENES: CAUSES, RECOGNITION, SAFE RECOVERY AND PREVENTION
2026-08-13
PSC FOCUS: 01324 – MATERIAL SAFETY DATA SHEETS: MSDS SHEETS MISSING FOR CHEMICALS IN STEERING GEAR LUBE OIL RACK.
2026-08-13
PSC FOCUS: 07108 – READY AVAILABILITY OF FIRE FIGHTING EQUIPMENT: FIRE EQUIPMENT ON B DECK FIRE LOCKER NOT READILY AVAILABLE.
2026-08-13
PSC FOCUS: 07110 – FIRE FIGHTING EQUIPMENT AND APPLIANCES: FIREFIGHTING HOSE BOX DAMAGED. CLOSING LATCHES MISSING AND BOX NOT CLOSED PROPERLY.
2026-08-13
PSC FOCUS: 07115 – FIRE-DAMPERS: STARBOARD SIDE AC ROOM FIRE DAMPERS TO BE FULLY OPERABLE FROM OUTSIDE
2026-08-13
SAFE ACCESS: GANGWAY ARRANGEMENT FOCUS AREAS: SAFETY NET & BULWARK LADDERS
2026-08-13
PSC FOCUS: TWO NINGBO DETENTIONS! “TO THE CONNECTION BETWEEN THE SLUDGE TANK DISCHARGE PIPING AND THE BILGE WATER PIPING” - TWO VESSELS WERE DETAINED ONE AFTER THE OTHER IN NINGBO, CHINA, FOR THE SAME DEFICIENCY: THE SLUDGE TANK DISCHARGE PIPING AND BILGE
2026-08-12
FOCUS ON LIFEBOAT REMOVE-CONTROL WIRE: PORT SIDE LIFEBOAT REMOTE OPERATION WIRE AND SUPPORT ARM WERE BROKEN DURING BOAT LOWERING DRILL LEAVING PORT SIDE BOAT, INCAPABLE OF BEING LOWERED BY CREW FROM INSIDE.
2026-08-10
FOCUS ON AN ALLISION “CONTACT DAMAGE DURING BERTHING: JETTY FENDER AND SHORE-SIDE ACCESS LADDER”
2026-08-10
PSC FOCUS: 07101 — FIRE PREVENTION STRUCTURAL INTEGRITY_PSCO OBSERVED WASTE OIL LEAK ON THE SLUDGE TANK GAUGE
2026-07-17
PSC FOCUS: 09209 - ELECTRICAL (CABLES & WIRING) - PSCO OBSERVED LOOSE AND EXPOSED WIRING FOR THE AUXILIARY BOILER SERVOMOTOR CONTROLLER — CABLES NOT SUPPORTED TO AVOID CHAFING OR DAMAGE.
2026-07-17
PSC FOCUS: 13108 - OPERATION OF MACHINERY - PSCO OBSERVED EXCESSIVE JACKET WATER LEAK ON THE MDE CLYINDER LINER #3 AND #4
2026-07-16
PSC FOCUS: 07199 - OTHER (FIRE SAFETY) - PSCO OBSERVED EXCESSICE FUEL OIL LEAKS FROM AUXILIARY ENGINE CYLINDERS.
2026-07-13
PSC FOCUS: 11104- RESCUE BOATS - PSCO OBSERVED EXCESSIVE HYDRAULIC LEAK FROM THE RESCUE BOAT DAVIT HYDRAULIC TANK, PROHIBITING PROPER OPERATION OF RESCUE BOAT DAVIT.
2026-07-13
PSC FOCUS: 11101 - LIFEBOATS - PSCO OBSERVED LIFEBOAT UNABLE TO START DUE TO LOW VOLTAGE IN BATTERIES AND FAULTY CHARGING CONNECTION.
2026-07-02
MAIN ENGINE UNDER-PISTON / SCAVENGE SPACE FIRE
2026-07-01
PSC FOCUS: 04114 - EMERGENCY SOURCE OF POWER - EMERGENCY GENERATOR_PSCO OBSERVED BATTERIES FOR EMERGENCY DIESEL GENERATOR PRIMARY START UNABLE TO CHARGE PROPERLY OR START THE EMERGENCY DIESEL GENERATOR WITH OUT PORTABLE CHARGING UNIT.
2026-06-30
PSC FOCUS: 07123 - OPERATION OF FIRE PROTECTION SYSTEM - FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED INOPERABLE EMERGENCY FIRE PUMP AND EXCESSIVE LEAKAGE FROM THE SHAFT PA
2026-06-25
INCIDENT FOCUS – PINCH POINT HAZARD (ENGINE ROOM SKYLIGHT HATCH COVER)
2026-06-25
PSC FOCUS: 07103 - DIVISION – DECKS, BULKHEADS AND PENETRATIONS - DRYING ROOM IS USED AS GENERAL STORE.
2026-06-25